<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Anesthesiology and Pain</title>
<title_fa>بیهوشی و درد</title_fa>
<short_title>JAP</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jap.iums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2228-6659</journal_id_issn>
<journal_id_issn_online>2322-3324</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی مقایسه ای چسبندگی انسولین رگولار به جدار ظروف سرمی شیشه ای و پلاستیکی</title_fa>
	<title>Comparative study of regular insulin adhesion to the walls of glass and plastic serum containers</title>
	<subject_fa>ترانسفیوژن و مایع درمانی</subject_fa>
	<subject>Transfusion and fluid therapy</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Original</content_type>
	<abstract_fa>&lt;strong&gt;&amp;nbsp;&amp;nbsp;مقدمه:&lt;/strong&gt;با توجه به نقش انسولین در کنترل قند خون و کاربرد وسیع آن،تنظیم دقیق میزان انسولینی که بایستی به بیمار برسد تا مریض در معرض عوارض ناشی از عدم تنظیم قند خون قرار نگیرد، بسیار ضروری می باشد.تحقیقات نشان داده که انتخاب نوع محلول وظروف سرمی به کاررفته درمیزان دستیابی بیماربه انسولین موثراست. هدف ما مقایسه میزان چسبندگی انسولین به جدارظروف شیشه ای و پلاستیکی میباشد.&lt;br&gt;
&lt;strong&gt;روش ها:&lt;/strong&gt;ابتدا 3 ظرف شیشه ای و پلاستیکی یک لیتری حاوی دکستروز5% تهیه ومیزان&lt;span dir=&quot;LTR&quot;&gt;300mu&lt;/span&gt; انسولین رگولار به آنها اضافه شد.به ظروف شماره 2و3شیشه&#8204;ای و پلاستیکی&lt;span dir=&quot;LTR&quot;&gt;2cc&lt;/span&gt; آلبومین و پلاسما اضافه شد.در زمان &lt;span dir=&quot;LTR&quot;&gt;0&lt;/span&gt; از انتهای ست وظرف نمونه برداری و سپس جریان &lt;span dir=&quot;LTR&quot;&gt;10cc/min&lt;/span&gt;برقرارودر زمان های 30-60 مجدداً نمونه برداری تکرارشد.غلظت انسولین در نمونه ها باکیت های انسولین بررسی و داده ها توسط آزمونهای مختلف تحلیل شد.&lt;br&gt;
&lt;strong&gt;یافته ها:&lt;/strong&gt;در زمان &lt;span dir=&quot;LTR&quot;&gt;&amp;nbsp;0&lt;/span&gt;در ظروف شیشه ای به میزان50% ودرظروف پلاستیکی75% چسبندگی ایجادشده است&lt;span dir=&quot;LTR&quot;&gt;(P&lt;0/05)&lt;/span&gt;. در زمان0تا 30میزان انسولین ظروف شیشه ای و پلاستیکی اختلاف معناداری ندارد&lt;span dir=&quot;LTR&quot;&gt;(P&gt;0/05)&lt;/span&gt;. میانگین انسولین در طی 60 دقیقه، در ظروف شیشه ای به طور معناداری کاهش&lt;span dir=&quot;LTR&quot;&gt;(P&lt;0/05)&lt;/span&gt; &amp;nbsp;ولی در ظروف پلاستیکی افزایش می یابد&lt;span dir=&quot;LTR&quot;&gt;(P&gt;0/05)&lt;/span&gt;. به طور کلی در طی یک ساعت روند تغییرات میانگین انسولین در دو ظرف معناداربود&lt;span dir=&quot;LTR&quot;&gt;(P&lt;0/05)&lt;/span&gt;.&lt;br&gt;
&lt;strong&gt;بحث :&lt;/strong&gt; بیشترین میزان چسبندگی جداری در زمان0اتفاق می افتد که این چسبندگی در ظروف پلاستیکی نسبت به شیشه ای به صورت معناداری بیشتراست.پس از گذشت یکساعت روندکاهشی درمیزان انسولین ظروف شیشه ای به صورت معنادار رخ می دهد در حالیکه در ظروف پلاستیکی میزان انسولین کمی افزایش می یابد.&lt;br&gt;
&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;کلیدواژه ها:&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt; انسولین،ظرف سرم،آلبومین،پلاسما&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;/span&gt;</abstract_fa>
	<abstract>&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;Introduction:&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;Due to the role of insulin in the control of blood sugar and its widespread use,it is very important to fine-tune the amount of insulin that should reach the patient so that the patient is not exposed to the complications of non-regulation of blood sugar.&lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;Research has shown that the choice of solution and serum containers is effective in the patient&amp;#39;s access to insulin.Our goal is to compare the degree of insulin adhesion to the walls of glass and plastic containers.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;Methods:&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;First,3 one-lit glass and plastic containers containing5%dextrose were prepared and300 mu of regular insulin was added to them.2cc albumin and plasma were added to glass and plastic containers No2-3.At time0,sampling was done from the end of the set,then the10cc/min flow was maintained and the sampling was repeated at 30-60min.Insulin concentration in the samples was assessed by insulin test kits and the data were analyzed by various tests.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;Results:&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;At time 0,50% adhesion was observed in glass containers and75% in plastic containers (P&lt;0.05).At 0-30,there was no significant difference in insulin levels between glass and plastic containers(P&gt;0.05).Mean insulin decreased significantly(P&lt;0.05)in glass containers during 60 min but increased(P&gt;0.05)in plastic containers.In general, during one hour,the trend of changes in mean insulin in containers was significant(P&lt;0.05).&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;Discussion:&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt; The highest amount of wall adhesion occurs at time0,which is significantly higher in plastic containers than glass.after one hour,a decrease in insulin content occurs significantly in glass containers,while in plastic containers,the amount of insulin increases slightly.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;Keywords:&lt;/strong&gt;Insulin,Serum Container,Albumin,Plasma</abstract>
	<keyword_fa>انسولین,ظرف سرم,آلبومین,پلاسما</keyword_fa>
	<keyword>Insulin,Serum Container,Albumin,Plasma</keyword>
	<start_page>132</start_page>
	<end_page>151</end_page>
	<web_url>http://jap.iums.ac.ir/browse.php?a_code=A-10-268-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>mehdi</first_name>
	<middle_name></middle_name>
	<last_name>izadi zaman abadi</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ایزدی زمان آبادی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mimi_izadi2@yahoo.com</email>
	<code>100319475328460018351</code>
	<orcid>100319475328460018351</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Anesthesiology Expert, Faculty of Anesthesiology Department, University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>متخصص بیهوشی و مراقبتهای ویژه ، گروه بیهوشی و مراقبت های ویژه دانشگاه علوم پزشکی اصفهان ، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>kamran</first_name>
	<middle_name></middle_name>
	<last_name>tavakkol</last_name>
	<suffix></suffix>
	<first_name_fa>کامران</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>توکل</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>dr.ktavakol@gmail.com</email>
	<code>100319475328460018352</code>
	<orcid>100319475328460018352</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Anesthesiology Expert, Assistant Professor in Faculty of Anesthesiology Department, Najaf Abad University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>متخصص بیهوشی و مراقبتهای ویژه ، استادیارگروه بیهوشی و مراقبت های ویژه دانشگاه علوم پزشکی نجف آباد، اصفهان ، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>ahmad</first_name>
	<middle_name></middle_name>
	<last_name>sobhani</last_name>
	<suffix></suffix>
	<first_name_fa>احمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سبحانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Drasobhani48@yahoo.com</email>
	<code>100319475328460018353</code>
	<orcid>100319475328460018353</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Internal Medicine Expert, Assistant Professor in Faculty of Internal Medicine Department, Najaf Abad University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>متخصص داخلی ، استادیارگروه داخلی دانشگاه علوم پزشکی نجف آباد ، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>atena</first_name>
	<middle_name></middle_name>
	<last_name>khayam bashi</last_name>
	<suffix></suffix>
	<first_name_fa>آتنا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خیام باشی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>atena_khayambashi2@yahoo.com</email>
	<code>100319475328460018354</code>
	<orcid>100319475328460018354</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Obstetrics and Gynecology Expert, Faculty of Obstetrics and Gynecology Department, University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>متخصص زنان و زایمان ، گروه زنان و زایمان دانشگاه علوم پزشکی اصفهان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
